Flow meter
Ultrasonic flowmeter
Electromagnetic Flowmeter
Vortex flowmeter
Intelligent precession vortex gas flow meter
Orifice flowmeter
Verabar Flowmeter
Turbine flowmeter
Thermal gas mass flowmeter
V cone flowmeter
Metal tube float flowmeter
Oval gear flowmeter
Annubar Flowmeter
Pressure gauge
Pressure generating device series
Pressure gauge series
Thermometers
Bimetal thermometer series
Thermocouple Thermal Resistance Series
Transmitter instrument
Smart transmitter handheld programmer
Intelligent differential pressure transmitter series
Level transmitter series
Diffusion silicon pressure transmitter series
Digital display instrument
Display regulator
Paperless recorder
Level / level instrument
Level instrument
Level instrument
Instrument ball valve
Wire and Cable

Address: No.333 Jianshe West Road, Jinhu County, Huaian City, Jiangsu Province
Postcode: 211600
Phone: 0517-86888834 86888835
Fax: 0517-86888835
Contact: Li Congquan
Online QQ: 253376250

Flow Meter-Oval Gear Flowmeter
click to view bigger image
Details of oval gear flowmeter :
a brief introdction
TC-TY series oval gear flowmeter : a type of volumetric flowmeter, especially suitable for heavy oil, polyvinyl alcohol, resin and other high viscosity medium flow measurement, so the oval gear flowmeter is also commonly known as oil meter. The elliptical gear flowmeter is a purely mechanical flowmeter. It is fully intrinsically safe and suitable for various hazardous situations. It has the function of local display and pulse transmitter remote transmission.
Detailed introduction of oval gear flowmeter
Details of TC-TY oval gear flowmeter :
TC-TY-A cast iron elliptic gear flowmeter, widely used in the measurement of various oil products and non-corrosive liquid media of cast iron
TC-TY-E type cast steel oval gear flowmeter for high pressure and low corrosive medium
TC-TY-B type is widely used in the measurement of highly corrosive liquid media, such as acid, alkali, salt and organic compounds. ◆ Technical data Ordinary cast iron (A), cast steel (E), stainless steel (B )
project
model
LC-A cast iron
LC-E cast steel
LC-B stainless steel
Nominal pressure
Mpa
1.0 1.6
2.5 4.0 6.4
1.0 1.6
Measured liquid viscosity
2 — 200 mPa.s
Measured liquid temperature
-20 ℃ ~ + 100 ℃
Flow range mh
model

Accuracy class
LC-A cast iron
LC-E cast steel
LC-B stainless steel
Nominal caliber (DNmm
0.5
0.2
0.5
0.2
0.5
0.2
10
0.04 ~ 0.4
0.1 ~ 0.4
0.04 ~ 0.4
0.1 ~ 0.4
0.1 ~ 0.5
0.1 ~ 0.5
15
0.25 ~ 1.5
0.3 ~ 1.5
0.25 ~ 1.5
0.3 ~ 1.5
0.3 ~ 1.5
0.3 ~ 1.5
20
0.5 ~ 3
0.6 ~ 3
0.5 ~ 3
0.6 ~ 3
0.6 ~ 3
0.6 ~ 3
25
1 to 6
1.2 ~ 6
1 to 6
1.2 ~ 6
1.2 ~ 6
1.2 ~ 6
40
2.5 ~ 15
3 ~ 15
2.5 ~ 15
3 ~ 15
3 ~ 15
3 ~ 15
50
4 ~ 24
4.8 ~ 24
4 ~ 24
4.8 ~ 24
4.8 ~ 24
4.8 ~ 24
65
5 ~ 40
8 ~ 40
5 ~ 40
8 ~ 40
8 ~ 40
8 ~ 40
80
10 ~ 60
12 ~ 60
10 ~ 60
12 ~ 60
12 ~ 60
12 ~ 60
100
16 to 100
20 ~ 100
16 to 100
20 ~ 100
20 ~ 100
20 ~ 100
150
32 ~ 190
38 ~ 190
32 ~ 190
38 ~ 190
38 ~ 190
38 ~ 190
200
34 ~ 340
68 ~ 340
34 ~ 340
68 ~ 340
68 ~ 340
68 ~ 340
product description:
TC-TY series oval gear flowmeter : a type of volumetric flowmeter, especially suitable for heavy oil, polyvinyl alcohol, resin and other high viscosity medium flow measurement , so the oval gear flowmeter is also commonly known as oil meter. The elliptical gear flowmeter is a purely mechanical principle flowmeter. It is completely intrinsically safe and suitable for various dangerous situations. The on-site display and remote transmission of the pulse transmitter function. Corrosion resistance, suitable for chemical and food hygiene industries. Oval gear flowmeters are extremely easy to install and maintain with accuracy levels of 0.3 and 0.5.

First, the working principle of TC-TY series oval gear flowmeter
Oval gear flowmeters are a type of positive displacement flowmeter, which is also called a displacement flowmeter. It is a class with higher accuracy in flow meters. It uses a mechanical measuring element to continuously divide the fluid into a single known volume portion, and measures the total volume of the flow according to the number of times the measurement chamber is filled and discharged successively and repeatedly. The positive displacement flowmeter is in principle a hydraulic engine that absorbs a small amount of energy from the fluid. This energy is used to overcome the friction of the rotation of the flow detection element and the attachment, and at the same time, a pressure drop is formed at the inflow and outflow of the meter.
The working principle of a typical elliptical-tooth flowmeter is shown in the figure: two elliptical gears have a special shape that rolls and rotates in contact with each other. P1 and p2 represent the inlet pressure and the outlet pressure respectively. Obviously p1> p2. The gear in the lower part of the figure (a) rotates counterclockwise due to the pressure difference between the two sides. The rotation torque is generated by the driven wheel, which is driven by the lower gear and rotates clockwise. In the position shown in Figure (b), both gears generate rotational torque under the action of differential pressure and continue to rotate. When installed in the position shown in Figure (c), the upper gear becomes the driving wheel, and the lower gear becomes the driven wheel. It continues to rotate to the same position as in Figure (a) to complete a cycle. The fluid volume of four crescent-shaped cavities surrounded by gears and the shell wall is discharged in one cycle. This volume is called the "circulation volume" of the flow meter.
Set the "circulation volume" of the flowmeter to υ, and the number of gear rotations within a certain period of time is N, then the volume of fluid flowing through the flowmeter during this time is V, then V = Nυ The rotation of the elliptical gear passes through the magnetic seal coupling and transmission The reduction mechanism passes to the counter to directly indicate the total amount flowing through the flowmeter. If the transmission device is added, it can be equipped with an electric display instrument to realize remote instantaneous flow or accumulated flow.

The working principle of the oval gear flowmeter is briefly summarized: the liquid flow is completed in the measurement chamber. There is a pair of oval gears in the measurement room. Under the action of the liquid pressure difference between the inlet and the outlet, the pair of oval gears keep rotating on the rotating shaft. After measuring the number of revolutions, the total amount of liquid flowing through the meter can be known.

Overview of TC-TY series oval gear flowmeter
Oval gear flowmeter is a volumetric flowmeter used for precise continuous or intermittent metering of the total flow of liquid flowing through a pipeline. The elliptic gear flowmeter consists of a measuring chamber equipped with a pair of oval gear rotors, a sealed coupling and a counting mechanism. Oval gear flowmeter is a field accumulating instrument. It has the advantages of simple structure, reliable use, high accuracy, small pressure loss, less influence by changes in liquid viscosity, large measuring range, and easy installation. This series of flow meters are mainly used in petroleum, chemical, oil products and other industries.

Technical parameters of TC-TY series oval gear flowmeter
1. Ordinary oval gear flowmeter: Housing material: cast iron housing, oval gear material: aluminum-magnesium alloy
Accuracy class
0.3 0.5
Nominal pressure
1.6Mpa
temperature
-10- + 80 ℃
model
Flow range m3 / h
DN
Measured liquid viscosity Mpa.s
mm
0.6-2
2-8
8-200
LC-10
10
0.05-0.25
0.04-0.25
0.025-0.25
LC-15
15
0.5-1.5
0.3-1.5
0.15-1.5
LC-20
20
0.75-3
0.4-3
0.3-3
LC-25
25
1.5-6
0.8-6
0.6-6
LC-40
40
3-15
2-15
1.5-15
LC-50
50
4.8-24
3-24
2.4-24
LC-80
80
12-60
8-60
6-60
LC-100
100
20-100
13-100
10-100
LC-150
150
38-190
24-190
19-190

2. Stainless steel elliptic gear flowmeter: The main material is made of stainless steel, which has strong corrosion resistance, and is suitable for chemical and food hygiene industries.
Accuracy class
0.5
Nominal pressure Mpa
1.6 2.5
Measured liquid temperature
-20- + 80 ℃
model
Flow range m3 / h
DN
Measured liquid viscosity Mpa.s
mm
0.6-2
2-8
8-200
LC-25B
25
2-6
1.26-8
1-6
LC-40B
40
5-15
3-15
2.5-15
LC-50B
50
8-24
4.8-24
4-24
LC-80B
80
15-40
8-40
6.5-40
four. Oval gear flowmeter dimensions
(I) Dimensions of cast iron type, cast iron high viscosity type, cast iron high temperature type, cast iron deformed oval gear flowmeter
Unit: mm
Nominal diameter
L
H
A
B
D
D1
N (a)
Φ
10
150
100
165
210
90
60
4
14
15
170
118
172
226
95
65
4
14
20
200
150
225
238
105
75
4
14
25
260
180
232
246
115
85
4
14
40
245
180
249
271
145
110
4
18
50
340
250
230
372
160
125
4
18
65
420
325
270
386
180
145
4
18
80
420
325
315
433
195
160
8
18
100
515
418
370
458
215
180
8
18
150
540
515
347
557
280
240
8
twenty three
200
650
650
476
720
335
295
12
twenty three
(II) Dimensions of cast steel type, cast steel high viscosity type, cast steel high temperature type oval gear flowmeter
Unit: mm
Nominal diameter
L
H
B
A
D
D1
N (a)
Φ
15
200
138
232
180
105
75
4
14
20
250
164
220
160
125
90
4
18
25
300
202
252
185
135
100
4
18
40
300
202
293
208
165
125
4
twenty three
50
384
262
394
312
175
135
4
twenty three
80
450
337
452
332
210
170
8
twenty three
100
555
442
478
310
250
200
8
25
150
540
510
557
347
300
250
8
26
200
650
650
720
476
36
310
12
26
Cast iron, cast steel high temperature oval gear flowmeter dimensions: DN15 ~ DN25, A and B dimensions according to the above table plus 160mm heat extension tube: DN40 ~ DN80, A and B dimensions according to the above table plus 300mm heat extension tube, the rest The dimensions are the same as in the table above.
(Three) stainless steel oval gear flowmeter dimensions
Unit: mm
Nominal diameter
L
H
B
A
D
D1
N (a)
Φ
15
208
120
228
172
95
65
4
14
20
236
150
238
225
105
75
4
14
25
287
195
246
232
115
85
4
14
40
265
178
349
265
145
110
4
18
50
265
178
349
265
160
125
4
18
65
365
260
436
319
180
145
4
18
80
420
305
459
324
200
160
8
18
100
515
400
554
373
220
180
8
18
150
540
515
607
397
280
240
8
twenty three
Five, the installation of flow meter
1. Clean the pipes thoroughly before installation, and install a filter in front of the flow meter to prevent debris from entering the flow meter. When the measured liquid contains gas, an air separator should be installed.
2. It should be noted that the elliptical gear axis of the flowmeter must be set to a horizontal position, that is, the dial is perpendicular to the ground plane. Regulate flow and start, closed valves should be installed at the inlet and outlet of the flowmeter.
3. The direction of the arrow on the flowmeter housing should be consistent with the liquid flow direction of the installed pipeline.
4. For continuous process pipelines, horizontal pipelines installed with flow meters should be equipped with bypass valves for regular cleaning and maintenance. Flow meters on vertical pipelines should be installed in the bypass pipeline to prevent debris from falling into the instrument.
5. Under the condition of correct installation of the flow meter, in order to facilitate reading, the counter can be rotated 180 o or 90 o according to requirements. See Figure 3 for installation requirements
Six, precautions for use:
1. Never test the flowmeter with water. 2. When starting or stopping, the opening and closing valve should be slow to prevent sudden impact and prevent reverse flow. 3. When the flowmeter is overhauled, the rear cover must not be disassembled, so as to avoid the change of accuracy during reassembly to affect accuracy.
Seven, error calculation and adjustment
(1) The basic error of the flow meter is calculated from the measured values at each verified flow point according to the following formula: (volume method) E = Vm-V / V ،ء 100%
E-flowmeter error (commonly referred to as cumulative error) takes two significant figures.
Vm-Measured value of flow meter (ie display value)
V-After correction, the measured value (ie the actual value) of the standard device of the flow meter is calculated from the basic error formula. When Vm> V, the basic error of the flow meter is a "+" value, indicating that the flow meter is moving faster.
When Vm <V, the basic error of the flow meter is a "-" value, indicating that the flow meter is slow.
In order to keep the flowmeter error within the basic error limit, an error is often required. That is, the mechanical transmission speed ratio is changed by replacing a pair of adjusting gears (adjusting teeth) installed in the counter, so that the display of the flow meter is worth adjusting.
The error adjustment cannot change the flow characteristics of the flowmeter, so that its characteristic curve is artificially in the new coordinate system.
In general, within the specified (or actually used) flow range, the basic error range of the maximum and minimum flow verification points is not greater than the basic error limit of the specified accuracy, and the basic error of the flowmeter can be qualified through error adjustment.
The flowmeters that have been used generally use the original adjustment gear set to perform error verification, and then perform error adjustment according to the specific error situation.
Eight, other
1. Stainless steel flowmeter is suitable for measuring 98% sulfuric acid, 60% nitric acid and 50% caustic soda.
2. This instrument is inspected with light diesel before leaving the factory. Do not use water calibration. The specific implementation is in accordance with the national measurement and verification regulations JJG235-90 oval gear flowmeter.
Nine, ordering instructions
1. Name and model. Specifications, materials,
2. Medium temperature, working pressure and flow range.
3. Medium viscosity value or medium name.
4. Are there any special requirements (such as explosion-proof)?
5. The name of the ordering and receiving unit.
6, detailed communication address, telephone, telegram, post code,
7. Settlement unit, bank account, account number.
8. Arrival station name, contact person.
9. You need to know more about the products, please call for information.
10. Three guarantees are implemented for our products, and follow-up maintenance during use period.
Ten, common failure causes, troubleshooting methods
Failure phenomenon
the reason
Measures
Note
Oval gear does not turn
1. There is debris in the pipe. 2. The tested liquid contains many impurities and the filter is damaged. Debris enters the watch and the gear gets stuck.
Remove and wash meters and pipes, repair filters.
Axial seal coupling leaks
Worn seal packing or lack of seal oil
Tighten the gland or replace the packing and fill with sealing oil.
Hand movement is unstable, or stop and go
Hands, pads, and other loose or rotating parts are not flexible
Retighten to eliminate inflexibility
Small flow error is too large
The elliptical gear collides with the wall of the metering box, the bearing is worn, or the metering box is deformed
Replace the bearing, repair the measuring box wall and gear at the changing gear, make the rotation flexible and ensure the required clearance.
Calibration after repair.
Excessive error change
The fluid is pulsating or contains gas.
Reduce pulsation or install gas separator
The error is too large, but the difference between the maximum and minimum errors does not exceed ،ہ 1%
The usage period has exceeded, or the gap has changed after maintenance.
Check again and adjust.
Sender no signal
1 Improper sending block position
Reposition left, right, back and forth
2 reverse polarity
Reconnect: 1. "+" to the red line 2. "-" to the black line.
Flowmeter ??ذاء¦²¶سم?? | Into Tongchuang | Hot Products | Products | News | Successful Cases | Technical Articles | Link System Chuang | Site Map |
Phone: 0517-86888834 86888835 Fax: 0517-86888835
Contact: Li Congquan Mobile: 13770434222
Address: No.333 Jianshe West Road, Jinhu County, Huaian City, Jiangsu Province
Copyright azurbus.com Jinhu Tongchuang Instrument Co., Ltd. Record number: 苏 ICP 备 10080562 号 -11